11
Technical data
Axis data
Operating Instructions – MOVIPRO
®
PHC11A-..M1-..2A-A1/..
99
Output data
Rated input power 2.2 kW/4.0 kW 1.6 kW 2.0 kW 2.2 kW/4.0 kW
Supply type AC three-phase
current
MOVITRANS
®
Rated output power 2.2 kW (3.0 HP) 1.6 kW (2.1 HP) 2.0 kW (2.7 HP) 2.2 kW (3.0 HP)
Operating mode S1 (IEC 60034‑1)
11.2 Axis data
PFA axis type MD022 MD040
Rated input power 1.6 kW 2.0 kW 2.2 kW 1.6 kW 2.0 kW 4.0 kW
S1 rated output power accord-
ing to EN 60034 at PWM fre-
quency = 4 kHz
1.6 kW 2.0 kW 2.2 kW 1.6 kW 2.0 kW 2.2 kW
Nominal output current 1.6 A 2.0 A 2.2 A 4.0 A 5.0 A 5.5 A
Current limiting (motor and re-
generative, duration depending
on the utilization)
8.25 A 14.05 A
Terminal designation X2011
Output voltage 3 × AC 0 – 500 V
"PWM frequency" Adjustable: 4 / 8 / 12 / 16 kHz
Speed range − 6000 – 0 – + 6000 rpm
Resolution 0.2 min
-1
over the entire range
Temperature sensors for single
drive
TF / TH / KTY
Maximum motor cable length 30 m (98 ft)
Installation altitude • Up to h < 1000 m (3281 ft) without restrictions
• At h ≥ 1000 m (3281 ft), the following restrictions apply:
– From 1000 m (3281 ft) to max. 4000 m (13120 ft):
I
N
reduction by 1% per 100 m (328 ft)
– From 2000 m (6562 ft) to max. 4000 m (13120 ft):
V
N
reduction by AC 6 V per 100 m (328 ft)
• Above 2000 m (6562 ft) for overvoltage class 2 only.
• External measures are required for overvoltage class 3.
• Overvoltage classes according to DIN VDE 0110-1.
Braking resistor
Connection voltage DC link voltage U
Z
, max DC 1000 V
Min. permitted braking resist-
ance (4Q operation)
68 Ω 33 Ω
Terminal designation X2301
20278543/EN – 09/2014