7
Electrical connections
Terminal strip
Operating Instructions – MOVIPRO
®
PHC11A-..M1-..2A-A1/..
52
7 Electrical connections
7.1 Terminal strip
WARNING
Risk of electric shock due to connecting or disconnecting plug connectors when volt-
age is applied.
Severe or fatal injuries.
• Disconnect all supply voltages.
• Make sure that the unit is de-energized.
• Never plug or unplug the plug connectors while they are live.
[17]
[3]
[4]
[5]
[7] [8] [11]
[10][9][1]
[16] [15]
[2]
[14][13][12][6]
12711962891
[1] Operating switch (optional)
[2] X4001, RS485 interface– system bus / X4101, CAN bus – system bus
[3] X4261, WLAN antenna (aux) / X4233, Ethernet fieldbus
[4] X4011, RS485 interface – external
[5] X5502, Safe disconnection – input
[6] X2292, Brake control (optional)
[7] X5001_2, Digital inputs/outputs – communication and control unit
[8] X5001_1, Digital inputs/outputs – communication and control unit
[9] X4223, Ethernet service interface
[10] X2011, Motor with brake control
[11] X2301, Braking resistor
[12] X2311, DC 24 V output / X2551, DC 24 V output for 2 voltage potentials
[13] X1011, MOVITRANS
®
THM20E pick-up / X1021, MOVITRANS
®
THM20C pick-
up (optional)
[14] X1011, MOVITRANS
®
THM20E pick-up / X1021, MOVITRANS
®
THM20C pick-
up / X1201, AC 400 V input
[15] X4111, CAN bus – external
[16] X4401, ID module
[17] X4211, WLAN antenna (main) (optional)
The following connections depend on the function modules installed in the unit:
• Braking resistors
• DC 24 V outputs
• Field communication
• Motors
• Supply
20278543/EN – 09/2014