EasyManua.ls Logo

SEW-Eurodrive MOVIPRO PHC11A-M1-2A-A1 Series - X5502: Safe Disconnection - Input

SEW-Eurodrive MOVIPRO PHC11A-M1-2A-A1 Series
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
Electrical connections
X5502: Safe disconnection – input
Operating Instructions – MOVIPRO
®
PHC11A-..M1-..2A-A1/..
82
7.25 X5502: Safe disconnection – input
WARNING
Risk of injury due to non-safety-related disconnection of the unit if the connection is
jumpered
Severe or fatal injuries
Jumper this connection only if the unit will not perform any safety functions ac-
cording to EN ISO 13849-1.
This connection is identified with a yellow ring.
The following table shows information about this connection:
Function
Input for safe disconnection
Connection type
M12, 5-pole, female, A-coded
Wiring diagram
1
4
3
2
5
9007201519557259
Assignment
No. Name Function
1 +24V DC 24 V output
2 STO- 0V24 reference potential for safe disconnection
3 0V24 0V24 reference potential
4 STO+ DC 24 V input for safe disconnection
5 res. Reserved
INFORMATION
Use only shielded cables for this connection.
20278543/EN – 09/2014