EasyManua.ls Logo

SEW-Eurodrive MOVIPRO PHC11A-M1-2A-A1 Series - Page 33

SEW-Eurodrive MOVIPRO PHC11A-M1-2A-A1 Series
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
Mechanical installation
Requirements
Operating Instructions – MOVIPRO
®
PHC11A-..M1-..2A-A1/..
33
Clearance Function Size
F: On the side (optional) Space for connection cables, plug connec-
tors, add-on elements and elements for op-
eration, e.g. maintenance switch
See dimension drawing
Horizontal installation
The following figure shows the required minimum clearance sizes of the unit:
B
Z
2
A
C
36028797483068939
[A] Housing cover clearance
[B] Clearance on the side
[C] Clearance below the cooling fins
[Z
1
] Housing cover clearance height
[Z
2
] Cooling fins clearance height
Refer to the following table for the minimum distance sizes and minimum clearance
sizes:
Clearance Function Size
A: Housing cover
Height Z
1
Space for display elements, diagnostics ele-
ments and actuator elements, e.g. service
unit
Z
1
= min. 150 mm (5.91 in)
B: On the side (optional) Space for connection cables, plug connec-
tors, add-on elements and elements for op-
eration, e.g. maintenance switch
See dimension drawing
B: Behind the cooling fins
Height Z
2
Space for optimum heat convection:
The cooling fins may not be located in a
closed hollow space.
Z
2
≥ 15 mm (0.59 in)
20278543/EN – 09/2014

Table of Contents