5
Mechanical installation
Requirements
Operating Instructions – MOVIPRO
®
PHC11A-..M1-..2A-A1/..
32
5.1.2 Minimum clearance
INFORMATION
• Observe the required minimum clearance for:
– The connection of the cables and plug connectors
– Handling of the display, diagnostics and operating elements
– Heat convection at the level of the cooling fins, if installed
• Refer to the dimension drawing in the chapter "Technical data" for information on
the required space.
Vertical installation
The following figure shows the required minimum clearance sizes of the unit:
9800168587
Refer to the following table for the minimum distance sizes and minimum clearance
sizes:
Clearance Function Size
A: Above Space for optimum heat convection:
The cooling fins may not be located in a
closed hollow space.
≥ 200 mm (7.9 in)
B: Behind the cooling fins Space for optimum heat convection ≥ 15 mm (0.59 in)
C: To the side on the right Space for connection cables, plug connec-
tors, add-on elements and elements for op-
eration, e.g. maintenance switch
See dimension drawing
D: Below Space for connection cables and plug con-
nectors
See dimension drawing
E: Unit cover Space for display elements, diagnostics ele-
ments and actuator elements, e.g. service
unit
≥ 150 mm (5.91 in)
20278543/EN – 09/2014