3.2.3 Product features and functions (overview)
Table 6: Overview of product features and functions of the device
Product feature/func‐
tion
Characteristic
Safety and ease of
use
Rugged, compact IP65 metal housing, CE marking (Europe)
Laser Class 2, laser switches off if the output power is exceeded
Automatic self-test on system start
Diagnostic tools for system setup and (remote) system monitoring
Configurable output of reading diagnostic data in two reading
results formats
Operating data polling, in case of error, issue of error code if
required
Activatable test string function (heartbeat) to signal that the device
is ready for operation
Password-protected configuration mode via SOPAS ET
Future-proof due to firmware update via data interface
Future-oriented SOPAS ET configuration software
Low power consumption
Additional supply voltage range
Optional parameter cloning using an external CMC600 parameter
cloning module in the CDB/CDM connection module
Convenient operation
and configuration
Configuration via SOPAS ET configuration software (online/offline)
or commands
Type-dependent configuration via GSD parameterization and via
CDF600-2xx for CLV61x-Fxxxx
LED status indicator
Deactivatable acoustic signaling device for confirming device func‐
tioning
Reading Operation
Mode
Start/stop operation (one bar-code bearing object per reading inter‐
val)
Read cycle
Pulse sources for start: Digital inputs, data interface (command),
auto pulse, free-running, CAN
Pulse sources for stop: Read cycle source, digital inputs, data inter‐
face (command), timer, condition
Bar code evaluation
All current 1D bar code types
Max. number of bar codes: 50 per reading interval
Separation of identical codes of the same code type using the read
angle
Data processing
Output of read data configurable through event-dependent evalua‐
tion conditions
Influencing the output string by filtering and output sorting
Data communication
Host interface: Two data output formats can be configured for the
reading result, can be switched to various physical interfaces, paral‐
lel operation possible
AUX interface: Fixed data output format that can be switched for
various physical interfaces
3.2.4 Operating principle
The device consists of a laser scanner (laser diode and optics), an electronics unit with
integrated decoder and various data interfaces (type-dependent) to industrial bus sys‐
tems. The use of various focusing settings, resolutions, scan processes, bus systems,
mounting options and optics enables use in most industrial applications. Interfaces to
external timers, such as photoelectric sensors or incremental encoders, enable reading
pulses independent of the control. The device makes the read results available for
further processing via its data interfaces.
3 PRODUCT DESCRIPTION
20
O P E R A T I N G I N S T R U C T I O N S | CLV61x 8017840/19OF/2021-10-28 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK CLV61 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK CLV61 Series and is the answer not in the manual?

SICK CLV61 Series Specifications

General IconGeneral
BrandSICK
ModelCLV61 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals