Protective field
hei
ght in mm
Typical power consumption of
sender in W
Typical power consumption of
receiver in W
1)
Resolution
14 mm
Resolution
30 mm
Resolution
14 mm
Resolution
30 mm
1650 2.04 1.25 4.08 2.50
1800 2.16 1.30 4.32 2.59
1950 2.28 1.34 4.56 2.69
2100 2.40 1.39 4.80 2.78
1)
Power discharged again via the OSSDs depending on the connected OSSD load must be added to the
table values.
12.4 Length of cable
Table 14: Maximum lengths of cable for wire cross-section 0.34 mm
2
, c
opper wire
Single system
Separate connecting cables for
sender and r
eceiver
b ≤ 85 m c ≤ 15 m
Connection of sender and receiver
v
ia T-connector on the sender
a + c ≤ 15 m
Connection of sender and receiver
v
ia T-connector on the receiver
a ≤ 15 m b ≤ 85 m
S Control cabinet with safety relay or safety controller
T T-connector
12.5 Table of weights
Table 15: Weight of sender and receiver
Protective field height in mm Weight in g
1)
s S
ender r Receiver
300 290 300
450 430 440
600 570 580
750 700 710
900 840 850
1050 970 980
1200 1110 1120
1350 1240 1250
1500 1380 1390
12 TECHNICAL DATA
60
O P E R A T I N G I N S T R U C T I O N S | deTec4 Core 8014253/ZOH3/2017-08-04 | SICK
Subject to change without notice