EasyManua.ls Logo

SICK DME5000

SICK DME5000
146 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 9 Operating Instructions
DME5000
112 © SICK AG • Germany • Subject to change without notice 8009813/ZJV1/2017-05
Technical Data
9.3 Technical Data DME5000-1xx
DME5000- 111 112 113 114 115 117
Part no.: 1022949 1023668 1025248 1025832 1025833 1028243
Measuring range 0.15 … 70 m
Accuracy ± 2 mm
Repeatability
1)
0.5 mm
Measured value output 1 ms 2 ms 2 ms 2 ms 2 ms 2 ms
Resolution data interface (adjustable) 0.05 … 5 mm
1/32 … 1
/2 mm
Resolution sin/cos (adjustable) 0.25 … 4 mm
Temperature drift (typ.) 0.1 mm/K
Temperature influence 1 ppm/K
Air pressure influence 0.3 ppm/hPa
Initialization time Type. 1.5 s 900 ms
Max. movement speed 10 m/s (< 1 m/s at reinitialization)
Supply voltage U
V
2)
DC 18 … 30 V
Residual ripple
3)
5 V
SS
Power intake (without heating) < 250 mA at DC 24 V
Light source Laser diode (red light)
Laser class 2 (EN 60825-1/C.D.R.H.)
Service life (at 25 °C) MTTF 50,000 h
Light spot diameter/distance max. 130 mm/70 m
Switching outputs MF1, MF2 B (push/pull)
Output (MF1/MF2) HIGH: U
V
‒ (< 3 V); LOW < 2 V
Input (MF1)
4)
HIGH: > 12 V; LOW < 3 V
Output current
5)
100 mA (short-circuit proof, overload proof)
Interfaces SSI PROFIBUS
®
12 MBd
RS-422 DeviceNet 500 kBd Hiperface
Operating ambience temperature 10 … +55 °C
Storage temperature 25 … +75 °C
Heating DME5000 121 122 123 124 Not
available
127
Part no. 1024083 1024084 1025249 1025836 1028244
Operating ambience temperature 40 … +55 °C
Power intake (with heating) < 1,000 mA at DC 24 V
Protection type IP 65
Electrical protection class VDE class 2 (rated voltage 32 V)
EMC EN 61000-6-2, EN 55011: Class B
Mechanic load Shock: EN 600 68-2-27/-2-29; Sine: EN 600 68-2-6; Noise: EN 600 68-2-64
Weight approx. 1650 g
1)
Statistic error 1 σ, ambience conditions consistent at minimum activation time: 10 min
2)
Protected against polarity reversal
3)
U
V
tolerances must not be exceeded or undercut
4)
Not protected against polarity reversal
5)
Max. 100 nF/20 mH