Operating Instructions Chapter 5
DME5000
8009813/ZJV1/2017-05 © SICK AG • Germany • Subject to change without notice 81
Commissioning
5.1.2 Alignment of Adjacent Distance Measuring Devices
To prevent mutual interference, the following minimum distances a must be kept.
5.1.3 Alignment of Distance Measuring Device with Adjacent Data Transmission
For ISD300 / ISD400-1xxx / ISD400-6xxx optical data transmission a minimum beam
distance of 100 mm independently of the maximum range s
max
must be kept.
Fig. 4: Alignment of adjacent
DME5000
Fig. 5: Alignment of adjacent
DME5000 and ISD
Reflector
Reflector
Reflector
DME
DME
DME
DME
Reflector
DME
ISD
ISD
Reflector
Parallel
mounting
a ≥ 100 mm + 0.01 x s
max.
[mm]
Anti
-parallel mounting
a ≥ 100 mm