40.4 Estrutura de dados de processos
Estrutura de dados de processos (versão 1.1)
WTB4FP MultiSwitchx-xxxxxxxxAxx:
A00 A70 A71 A72 A73 A75
IO-Link V1.1
Process
data
2 Byte 4 Byte
Byte 0 : Bit 15... 8
Byte 1: Bit 7... 0
Byte 0 : Bit 31...
24
Byte 1: Bit 13... 16
Byte 2: Bit 15... 8
Byte 3: Bit 7... 0
Bit 0/ Data
type
Q
L1
/ Boolean
Bit 1/ Data
type
Q
L2
/ Boolean Qint.1 /
Boolean
Q
L2
/ Boo‐
lean
Qint.1 / Boolean
Bit... / Des‐
cription /
Data type
2...15 /
[empty]
2...15 /
[Time
measure‐
ment
value] /
UInt 14
2 … 15 /
[Counter
value] /
UInt 14
2 … 15 /
[Length /
speed
measure‐
ment] /
SInt14
2 /
Qint.1 /
Boolean
2…7 / [empty]
Bit... / Des‐
cription /
Data type
3 … 15 /
[Time
measure‐
ment
value] /
UInt13
8 … 31 / [Carrier
load] / UInt 24
41 Eliminação de falhas
A tabela Eliminação de falhas mostra as medidas a serem executadas, quando o
sensor não estiver funcionando.
Tabela 12: Eliminação de falhas
Indicador LED / padrão de
erro
Causa Medida
LED verde intermitente Comunicação IO-Link Nenhuma
As saídas de comutação não
se comportam de acordo com
a
figura X
1. Comunicação IO-Link
2. Alteração da configuração
3. Curto-circuito
1. Nenhuma
2. Adaptação da configuração
3. Verificar as conexões elétri‐
cas
LED amarelo aceso, nenhum
objeto no caminho óptico
A distância de comutação é
ajustada com uma distância
grande demais
Reduzir a distância de
comutação
Objeto está no caminho
óptico, LED amarelo apagado
Distância entre sensor e
objeto é grande demais ou
distância de comutação foi
ajustada para um valor baixo
demais
Aumentar a distância de
comutação
COLOCAÇÃO EM OPERAÇÃO 40
8025665 / 2020-11-13 | SICK