0
20
(0.79)
10
(0.39)
40
(1.57)
30
(1.18)
50
(1.97)
80
(3.15)
40
(1.57)
120
(4.72)
160
(6.30)
200
(7.87)
240
(9.45)
0
y
x
y
x
Minimum distance in mm (y) between the set sensing
range and white background (90 % remission)
Example:
Safe suppression of the background
White background (90 %)
Black object (6 % remission)
Set sensing range x = 120 mm
Needed minimum distance to white
background y = 7 mm
Distance in mm (inch)
Recommended sensing range for
the best performance
60
(2.36)
90%/90%
18%/90%
1
6%/90%
33
2
Figure 4: Characteristic line
0
8
15
7
15
4 220
Distance in mm (inch)
210
215
1
2
3
80
(3.15)
40
(1.57)
120
(4.72)
160
(6.30)
200
(7.87)
240
(9.45)
15
D
C
A B
BluePilot
E
F
Figure 5: bar graph
A Sensing range min. in mm
B Sensing range max. in mm
C Viewing range
D Adjustable switching threshold for fore‐
ground suppression
E Sensing range indicator
F Teach-Turn adjustment
Figure 6: Light spot size
7.3 Setting
Sensing range adjustment
WTB4Fx-xxxxxx2xAxx
1 7
2
6
3 4 5
4 operating mode: 2 switching points
1 - 3 Q
L1
active
5 - 7 Q
L2
active
7 Distance value via Io-Link
1 - 6 off
WTB4Fx-xxxxxx50Xxx2
COMMISSIONING 7