EasyManuals Logo

Siemens MICROMASTER 430 Manual

Siemens MICROMASTER 430
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #106 background imageLoading...
Page #106 background image
Applicable Standards
MICROMASTER 430 Operating Instructions
6SE6400-5AC00-0BP0
105
I Applicable Standards
European Low Voltage Directive
The MICROMASTER product range complies with the requirements of the Low
Voltage Directive 73/23/EEC as amended by Directive 98/68/EEC. The units
are certified for compliance with the following standards:
EN 60146-1-1 Semiconductor inverters – General requirements and line
commutated inverters
EN 60204-1 Safety of machinery - Electrical equipment of machines
European Machinery Directive
The MICROMASTER inverter series does not fall under the scope of the
Machinery Directive. However, the products have been fully evaluated for
compliance with the essential Health & Safety requirements of the directive
when used in a typical machine application. A Declaration of Incorporation is
available on request.
European EMC Directive
When installed according to the recommendations described in this manual,
the MICROMASTER fulfils all requirements of the EMC Directive as defined by
the EMC Product Standard for Power Drive Systems EN 61800-3.
Underwriters Laboratories
UL and CUL LISTED POWER CONVERSION EQUIPMENT 5B33 for use in a
pollution degree 2
ISO 9001
Siemens plc operates a quality management system, which complies with the
requirements of ISO 9001.
www.eltra-trade.com
+421 552 601 099
info@eltra-trade.com

Table of Contents

Other manuals for Siemens MICROMASTER 430

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MICROMASTER 430 and is the answer not in the manual?

Siemens MICROMASTER 430 Specifications

General IconGeneral
Power Range7.5 kW to 250 kW
Voltage Range380V to 480V
Frequency Range0 Hz to 650 Hz
Protection ClassIP20
Input Frequency47 Hz to 63 Hz
Digital Inputs6
Cooling MethodForced-air cooling
CommunicationUSS
Protection FeaturesOvervoltage, undervoltage, overcurrent, short-circuit, ground fault, overtemperature
Analog Inputs2
Digital Outputs3
Analog Outputs2
Ambient Temperature-10°C to +50°C
Control TypeSensorless vector control