5 System parameters
MICROMASTER 430 Operating Instructions
60 6SE6400-5AC00-0BP0
5.3 Parameter list (short form)
Explanatory information on following table:
Ø Default: Factory setting
Ø Level: Access level
Ø DS Inverter status (Drive State), indicates the inverter state in which a
parameter can be modified (see P0010).
C Commissioning
URun
T Ready to run
Ø QC Quick Commissioning
Q Parameter can be modified in the Quick Commissioning state.
N Parameter cannot be modified in the Quick Commissioning state.
Always
ParNr ParText Default Level DS QC
r0000 Drive display - 1 - -
P0003 User access level 1 1 CUT N
P0004 Parameter filter 0 1 CUT N
P0010 Commissioning parameter 0 1 CT N
Inverter Unit (P0004 = 2)
ParNr ParText Default Level DS QC
P0100 Europe / North America 0 1 C Q
P3900 End of quick commissioning 0 1 C Q
Parameter Reset
ParNr ParText Default Level DS QC
P0970 Factory reset 0 1 C N
Inverter Unit (P0004 = 2)
ParNr ParText Default Level DS QC
r0018 Firmware version - 3 - -
r0026[1] CO: Act. DC-link voltage - 3 - -
r0037[2] CO: Inverter temperature [°C] - 3 - -
r0039 CO: Energy consumpt. meter [kWh] - 3 - -
P0040 Reset energy consumption meter 0 3 CT N
r0200 Act. power stack code number - 3 - -
P0201 Power stack code number 0 3 C N
r0203 Act. inverter type - 3 - -
r0204 Power stack features - 3 - -
r0206 Rated inverter power [kW] / [hp] - 3 - -
r0207 Rated inverter current - 3 - -
r0208 Rated inverter voltage - 3 - -
r0209 Maximum inverter current - 3 - -