Page #7 background imageLoading...
Page #7 background image
Definitions and Warnings
MICROMASTER 430 Operating Instructions
6 6SE6400-5AC00-0BP0
Definitions and Warnings
DANGER
indicates an immiently hazardous situation which, if not avoided, will result in
death or serious injury.
WARNING
indicates a potentially hazardous situation which, if not avoided, could result in
death or serious injury.
CAUTION
used with the safety alert symbol indicates a potentially hazardous situationwhich,
if not avoided, may result in minor or moderate injury.
CAUTION
used without safety alert symbol indicates a potentially hzardous situation which, if
not avoided, may result in a property demage.
NOTICE
indicates a potential situation which, if not avoided, may result in an undesireable
result or state.
NOTE
For the purpose of this documentation, "Note" indicates important information
relating to the product or highlights part of the documentation for special
attention.
Qualified personnel
For the purpose of this Instruction Manual and product labels, a "Qualified
person" is someone who is familiar with the installation, mounting, start-up and
operation of the equipment and the hazards involved.
He or she must have the following qualifications:
1. Trained and authorized to energize, de-energize, clear, ground and tag
circuits and equipment in accordance with established safety procedures.
2. Trained in the proper care and use of protective equipment in accordance
with established safety procedures.
3. Trained in rendering first aid.
PE
= Ground
PE – Protective Earth uses circuit protective conductors sized for short circuits
where the voltage will not rise in excess of 50 Volts. This connection is
normally used to ground the inverter.
- Is the ground connection where the reference voltage can be the same
as the Earth voltage. This connection is normally used to ground the motor.
Use for intended purpose only
The equipment may be used only for the application stated in the manual and only
in conjunction with devices and components recommended and authorized by
Siemens.
www.eltra-trade.com
+421 552 601 099
info@eltra-trade.com

Table of Contents

Other manuals for Siemens MICROMASTER 430

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MICROMASTER 430 and is the answer not in the manual?

Siemens MICROMASTER 430 Specifications

General IconGeneral
Power Range7.5 kW to 250 kW
Voltage Range380V to 480V
Frequency Range0 Hz to 650 Hz
Protection ClassIP20
Input Frequency47 Hz to 63 Hz
Digital Inputs6
Cooling MethodForced-air cooling
CommunicationUSS
Protection FeaturesOvervoltage, undervoltage, overcurrent, short-circuit, ground fault, overtemperature
Analog Inputs2
Digital Outputs3
Analog Outputs2
Ambient Temperature-10°C to +50°C
Control TypeSensorless vector control