Property Description
Switch over in the event
of a terminal bus failure
Approved network adapters are used for a redundant connection of the PC
stations to a terminal bus
1)
:
Onboard network adapters
2 )
Standard network adapters (INTEL)
2 )
Switch over in the event
of a system bus failure
Approved network adapters are used for a redundant connection of the PC
stations to a system bus
1)
:
Onboard network adapters
2 )
Standard network adapters (INTEL)
2 )
Communications processors CP 16xx
2)
1)
You can find additional information in the product overview
Process Control System PCS 7; Released
Modules
.
2)
You can find additional information on this in the manual
Process Control System PCS 7; Fault-
tolerant Process Control Systems
.
Recommendations
You should always use redundant server pairs when the availability of the respective
application is critical to your PCS 7 plant.
If PC stations of a PCS 7 plant are integrated into a domain, we recommend that you use
multiple domain controllers.
Additional information
You can find information about the client-server architecture in the "Differences between
multiple station systems and single station systems (Page 17)" section.
You can find information on how to activate redundancy in the "Configuring redundancy for
redundant servers (Page 81)" section.
You can find information about activating redundancy for operator stations in the manual
Process Control System PCS 7; Fault-Tolerant Process Control Systems
.
You can find information about configuring and implementing redundancy for BATCH
stations in the manual
Process Control System PCS 7; SIMATIC BATCH
.
You can find information about configuring and implementing redundancy for Route Control
stations in the manual
Process Control System PCS 7; SIMATIC Route Control
.
3.3 Possible ways to operate engineering stations
Working with multiple PCs
You have a variety of options available when working on engineering stations to engineer
PCS 7 systems. You can, for example, use more than one PC when engineering a PCS 7
system if a single PC is inadequate for the job.
PC components of a PCS 7 system
3.3 Possible ways to operate engineering stations
PCS 7 - PC Configuration (V8.2)
16 Installation Manual, 03/2016, A5E36200050-AB