Configuration / diagnostics using remote mechanisms
6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)
SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19
181
You can save the event table using HTTP or TFTP in the System menu.
Note
Note that eve
nts occurring in quick succession are not always displayed in the causal
sequence.
Figure 6-17 "System Event Log Table" dialog
Syntax of the Command Line Interface
Table 6- 10 System Event Log Table- CLI\SYSTEM\LOG>
Command Description Comment
info Displays information on the log table
configuration.
events <show¦clear> Indicates or erases expired events in
memory.
Administrator only.
eventmax [Max count] Specifies the maximum number of events
in the log table. A maximum of 10 to 400
entries can be set.
Administrator only.