Technical specifications
SCALANCE X-200
278 Operating Instructions, 12/2011, A5E00349864-19
Table 10- 4 Optical data
Device type
SCALANCE
Optical transmit power Receiver sensitivity
X204-2
X204-2TS
XF204-2
X206-1
XF206-1
X212-2
X202-2IRT
-19 / -17 / -14 dBm
(min. / typ. / max.)
-34 / -32 dBm
(typ. / max.)
X204-2LD
X206-1LD
X212-2LD
-15 / -7 dBm
(min. / max)
-34 dBm
(max.)
X202-2P IRT PRO
X201-3P IRT PRO
X202-2P IRT
X201-3P IRT
X200-4P IRT
-8 / -4.5 / -2 dBm
(min. / typ. / max.)
-23 / -25 dBm
(min. / typ.)
Table 10- 5 Signaling contact
Voltage for the signaling contact 24 VDC
Current through the signaling contact max. 100 mA*
*For X204-2TS max. 50 mA.