2.4 ETU300 electronic trip unit
3WA1 air circuit breaker
86 Equipment Manual, 02/2023, 92310000002-06
2.4.4.3 Parameter DAS+ maintenance mode
Parameters
DAS+ maintenance mode
Current setting I
i DAS+
1.5 x I
n
Activation via ETU input
2.4.5 DAS+ maintenance mode
The DAS+ maintenance mode can be activated for the ETU300 electronic trip unit via
the digital ETU input. The input signal must have the signal state HIGH for this purpose.
The activated DAS+ maintenance mode is indicated by the blue DAS+ LED on the
ETU300.
The digital ETU output of the circuit breaker is set when the DAS+ maintenance mode is
switched on.
The connection is made at the secondary disconnect terminal system of the 3WA air
circuit breaker.
Digital input ETU-IN
Connection
X8-5 and X8-6
Floating output ETU-OUT
Connection
X8-7 and X8-8