Measurement of residual current and PE conductor current through external summation
curr
ent transformer
2)
Measurement of physical variables (e.g. temperature, pressure, humidity) with external
0/4mA to 20mA transmitter
1) 2)
1)
This function will be available at a later time via a FW update.
2)
Using optionally available expansion module "I(N), I(DIFF), Analog" (MLFB:
7KM9200-0AD00-0AA0)
Manual 7KM PAC expansion module I(N),
I(Di󹪜), analog (
https://support.industry.siemens.com/cs/document/109746834/
ger%C3%A4tehandbuch-7km-pac-erweiterungsmodul-i(n)-i(di󹪜)-analog?dti=0&lc=de-DE)
Counter
s and power demand
A total of 50 energy counters capture reactive energy, apparent energy, and active energy for
o󹪜-peak and on-peak, import and export on a phase-speci󹪝c basis.
Energy consumption for active energy, reactive energy and apparent energy per day and
tari󹪜.
Two con󹪝gurable universal counters
1)
for counting
Limit violations
Status changes at the digital input
Status changes at the digital output
Pulses of a connected pulse encoder (e.g. from electricity, gas, or water meters). The
pulse shape and time response must correspond to the signal shape described in the
IEC62053-31 standard.
Operating hours counter
1)
for monitoring the operating time of a connected load. Counts
only in the case of energy counting above an adjustable threshold.
One apparent energy counter, one active energy counter, and one reactive energy counter
for detecting the total energy import, regardless of the active tari󹪜 for display on the device.
One apparent energy counter, one active energy counter, and one reactive energy counter
for detecting the power consumption of a manufacturing process. The process energy
counters can be started and stopped by means of the available digital inputs.
Operating hours counter
1)
for recording the duration of a manufacturing process. The start
and stop commands of the digital input that controls the process energy counter start and
stop the operating hours counter. Up to 10counters can be used for detecting the
consumption of any media via digital inputs if the optionally available SENTRON PAC 4DI/2DO
expansion modules are used. Consumption (e.g. of gas, water, compressed air, electrical
current) can thus be recorded using simple media counters with a pulse output.
The display texts can be freely parameterized in a user-friendly way using
the SENTRONPowercon󹪝g (
https://mall.industry.siemens.com/mall/en/WW/Catalog/Products/
10121795) con󹪝guration sof
tware.
1)
This function will be available at a later time via a FW update.
Description
2.1Performance features
PAC4220
16 Equipment Manual, L1V30827278B-01

Table of Contents

Related product manuals