Configuring with Web Based Management
4.4 "System" menu
SCALANCE SC-600 Web Based Management (WBM)
198 Configuration Manual, 10/2021, C79000-G8976-C475-03
Configuration procedure
1. To use the functionality, select the corresponding check box.
2. Click the "Set Values" button.
See also
Upkeep and maintenance (Page 347)
4.4.13 Syslog client
On this page, you configure the Syslog client. The Syslog messages can be sent to the
Syslog server unencrypted or encrypted.
Requirements for sending Syslog messages
• The Syslog client is enabled.
• In "System > Events > Configuration", "Syslog" is activated for the relevant event.
• There is a Syslog server in your network that receives the Syslog messages.
• The IP address or the FQDN (Fully Qualified Domain Name) of the Syslog server is
entered in the device.
Description
The page contains the following boxes:
• Syslog Client
Enable or disable the Syslog client on the device.
• Syslog Server Address
Enter the IP address, the FQDN (Fully Qualified Domain Name) or the host name of
the Syslog server.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC632-2C and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC632-2C Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC632-2C
CategorySwitch
LanguageEnglish

Related product manuals