Technical basics
3.1 IP address
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
35
Network gateway (router)
The task of the network gateways (routers) is to connect the IP subnets. If an IP
datagram is to be sent to another network, it must first be sent to a router. For make this
possible, you need to enter the router address for each member of the IP subnet.
The IP address of a device in the subnet and the IP address of the network gateway
(router) may only be different at the points where the subnet mask is set to "0".
3.1.2 IPv4
IPv4
IP configuration
• DHCP Server
• Manual
Available IP addresses
32-bit: 4, 29 * 10
9
addresses
Address format
Decimal: 192.168.1.1
with port: 192.168.1.1:20
Loopback
127.0.0.1
IP addresses of the interface
4 IP addresses
Header
• Checksum
• Variable length
• Fragmentation in the header
• No security
Fragmentation
Host and router
Quality of service
Type of Service (ToS) for prioritization
Types of frame
Broadcast, multicast, unicast
Identification of DHCP clients/server
Client ID:
• MAC address
• DHCP client ID
• System name
• PROFINET station name
• IAID and DUID
DHCP
via UDP with broadcast
Resolution of IP addresses in hardware addresses
ARP (Address Resolution Protocol)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC632-2C and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC632-2C Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC632-2C
CategorySwitch
LanguageEnglish

Related product manuals