EasyManua.ls Logo

Siemens SIMATIC NET SCALANCE SC632-2C

Siemens SIMATIC NET SCALANCE SC632-2C
372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring with Web Based Management
4.7 "Security" menu
SCALANCE SC-600 Web Based Management (WBM)
338 Configuration Manual, 10/2021, C79000-G8976-C475-03
4.7.7.2 Connections
On this WBM page, you configure the basic settings for the OpenVPN connection. You
specify the security settings on the WBM page "Authentication".
Description
Connection name
Enter a unique name for the OpenVPN connection and click "Create" to create a new
connection.
The table contains the following columns:
Select
Select the check box in the row to be deleted.
Name
Shows the name of the OpenVPN connection.
Operation
Specify how the connection is established.
start
The device attempts to establish a VPN connection to the partner.
start on DI
If the event "Digital In" occurs, the device attempts to establish a VPN connection
to the partner.
This is on condition that the event "Digital In" is forwarded to the VPN connection.
To do this in "System > Events> Configuration" activate "VPN Tunnel" for the
"Digital In" event.
Disabled
The VPN connection is disabled.