EasyManua.ls Logo

Siemens SIMATIC NET SCALANCE SC632-2C

Siemens SIMATIC NET SCALANCE SC632-2C
372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring with Web Based Management
4.5 "Layer 2" menu
SCALANCE SC-600 Web Based Management (WBM)
238 Configuration Manual, 10/2021, C79000-G8976-C475-03
Restoring factory settings
If you have restored the factory defaults, ring redundancy is disabled and the default
ports are used as the ring ports. This can lead to circulating frames and failure of the
data traffic if other settings were used in a previous configuration.
4.5.5 Spanning Tree
4.5.5.1 General
General settings of the Spanning Tree protocol
On this page, you can enable Spanning Tree and select the protocol compatibility. By
default, the "Spanning Tree Protocol" (STP) is enabled.
Description of the displayed boxes
The page contains the following boxes:
Spanning Tree
Enable or disable Spanning Tree.
Note
No operation of Spanning Tree with enabled ring redundancy
If ring redundancy is enabled under "Layer 2", Spanning Tree cannot be used.
Protocol Compatibility
Select the protocol compatibility. The following settings are available:
STP
RSTP

Table of Contents