Configuring with Web Based Management
4.6 "Layer 3" menu
SCALANCE SC-600 Web Based Management (WBM)
262 Configuration Manual, 10/2021, C79000-G8976-C475-03
4.6.1.2 Configuration
On this page, you configure the subnet for the interface.
Description
The page contains the following:
Interface (Name)
Select the interface from the drop-down list.
Status
Enable or disable the interface.
Interface Name
Enter the name of the interface.
MAC Address
Displays the MAC address of the selected interface.
DHCP
Enable or disable the DHCP client for this IPv4 interface.
Note
If you want to operate the device as a router with several interfaces, disable DHCP on
all interfaces.
IP Address
Enter the IPv4 address of the interface. The IPv4 addresses must not be used more
than once.
Subnet Mask
Enter the subnet mask of the subnet you are creating. Subnets on different interfaces
must not overlap.