Configuring with Web Based Management
4.4 "System" menu
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
209
4.4.15.2 Link Change
Configuration of fault monitoring of status changes on connections
On this page, you configure whether or not an error message is triggered if there is a
status change on a network connection.
If connection monitoring is enabled, an error is signaled
• when there should be a link on a port and this is missing.
• or when there should not be a link on a port and a link is detected.
A fault causes the fault LED on the device to light up and, depending on the
configuration, can trigger a trap or an entry in the event log table.
Description
Table 1 has the following columns:
• 1st column
Shows that the settings are valid for all ports.
• Setting
Select the setting from the drop-down list. You have the following setting options:
– "-" (disabled)
– Up
– Down
– No Change: The setting in table 2 remains unchanged.
• Copy to Table
If you click the button, the setting is adopted for all ports of table 2.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC632-2C and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC632-2C Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC632-2C
CategorySwitch
LanguageEnglish

Related product manuals