Configuring with Web Based Management
4.4 "System" menu
SCALANCE SC-600 Web Based Management (WBM)
202 Configuration Manual, 10/2021, C79000-G8976-C475-03
Deviating display of the transmission parameters with combo ports
In the connection status "down", the displayed transmission parameters do not match
the actual values of the combo port. In the connection status "up", the correct values are
displayed.
Initial situation
A pluggable transceiver is plugged into the combo port with the following settings:
• Combo Port Media Type: auto
• Status: enabled
• Link: down
Display of the transmission parameters
With 100 Mbps pluggable transceivers
• Actual response: Mode: 100M HD
• Expected response: Mode: 100M FD
With 1 Gbps pluggable transceivers
• Actual response: Mode: 1G HD
• Expected response: Mode: 1G FD