Configuring with Web Based Management
4.5 "Layer 2" menu
SCALANCE SC-600 Web Based Management (WBM)
232 Configuration Manual, 10/2021, C79000-G8976-C475-03
Description
The page contains the following boxes:
Base Bridge Mode
802.1Q VLAN Bridge
Sets the mode "VLAN-aware" for the device. In this mode, VLAN information is
taken into account.
VLAN ID
Enter the VLAN ID in the "VLAN ID" input box.
Range of values: 1 ... 4094
The table has the following columns:
Select
Select the row you want to delete.
VLAN ID
Shows the VLAN ID. The VLAN ID (a number between 1 and 4094) can only be
assigned once when creating a new data record and can then no longer be changed.
To make a change, the entire data record must be deleted and created again.
Name
Enter a name for the VLAN. The name only provides information and has no effect on
the configuration. The length is a maximum of 32 characters.