EasyManua.ls Logo

Siemens SIMATIC NET SCALANCE SC632-2C

Siemens SIMATIC NET SCALANCE SC632-2C
372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring with Web Based Management
4.5 "Layer 2" menu
SCALANCE SC-600 Web Based Management (WBM)
254 Configuration Manual, 10/2021, C79000-G8976-C475-03
Description of the displayed boxes
The page contains the following boxes:
VLAN ID
If you click on this text box, a drop-down list is displayed. Here you can select the
VLAN ID of a new MAC address you want to configure.
MAC address
Here you enter a new MAC multicast address you want to configure.
The table has the following columns:
Select
Select the row you want to delete.
MAC address
Here, the multicast address is displayed that the device has learned or the user has
configured.
Status - Static
Shows the status of each address entry. The address was entered statically by the
user. Static addresses are stored permanently; in other words, they are not deleted
when the Aging-Time expires or when the device is restarted. These must be deleted
by the user.
Configuration procedure
Creating a new entry
1. Select the required VLAN ID from the ""drop-down list.
2. Enter the MAC address in the "MAC address" input box.
3. Click the "Create" button. A new entry is generated in the table.
4. Assign the relevant ports to the MAC address.
5. Click the "Set Values" button.

Table of Contents

Related product manuals