Configuring with Web Based Management
4.7 "Security" menu
SCALANCE SC-600 Web Based Management (WBM)
296 Configuration Manual, 10/2021, C79000-G8976-C475-03
Primary Server
Using the options in the drop-down list, specify whether or not this server is the
primary server. You can select one of the options "yes" or "no".
Test
With this button, you can test whether or not the specified RADIUS server is available.
The test is performed once and not repeated cyclically.
Test Result
Shows whether or not the RADIUS server is available:
Not reachable
The IP address is not reachable.
The IP address is reachable, the RADIUS server is, however, not running.
Reachable, key not accepted
The IP address is reachable, the RADIUS server does not, however accept the
shared secret.
Reachable, key accepted
The IP address is reachable, the RADIUS server accepts the specified shared
secret.
Procedure
Entering a new server
1. Click the "Create" button. A new entry is generated in the table.
The following default values are entered in the table:
RADIUS Server Address: 0.0.0.0
Server Port: 1812
Max. Retrans.: 3
Primary server: No
2. In the relevant row, enter the following data in the input boxes:
RADIUS Server Address
Server Port
Shared Secret
Shared Secret Conf
Max. Retrans.: 3
Primary server: No
3. If necessary check the reachability of the RADIUS server.
4. Click the "Set Values" button.
Repeat this procedure for every server you want to enter.