EasyManuals Logo

Siemens SIMATIC NET SCALANCE SC632-2C User Manual

Siemens SIMATIC NET SCALANCE SC632-2C
372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #366 background imageLoading...
Page #366 background image
Appendix A
A.3 Syslog messages
SCALANCE SC-600 Web Based Management (WBM)
366 Configuration Manual, 10/2021, C79000-G8976-C475-03
Nonrepudiation
Message text
Device configuration changed.
Example
Device configuration changed.
Explanation
The device configuration has been changed permanently.
Severity
Info
Facility
local0
Standard
IEC 62443-3-3 Reference: SR2.12
Communication integrity
Message text
[IKE] {connection name} {config detail} received invalid DPD sequence
number {config detail} (expected {config detail}), ignored.
Example
[IKE] "c1" "1" received invalid DPD sequence number 10 (expected 12),
ignored.
Explanation
Integrity check failed (IPsec)
Severity
Error
Facility
local0
Standard
IEC 62443-3-3 Reference: SR 3.1
Message text
OVPN_{connection name}{config detail}: Authenticate/Decrypt packet error:
packet HMAC authentication failed.
Example
OVPN_c1[25409]: Authenticate/Decrypt packet error: packet HMAC
authentication failed.
Explanation
Integrity check failed (OpenVPN).
Severity
Error
Facility
local0
Standard
IEC 62443-3-3 Reference: SR 3.1
Restoration of the automation system
Message text
{protocol}: Loaded file type Firmware {version} (restart required).
Example
TFTP: Loaded file type Firmware V02.00.00 (restart required).
Explanation
The firmware was successfully loaded.
Severity
Notice
Facility
local0
Standard
IEC 62443-3-3 Reference: SR7.4
Message text
{protocol}: User {user name} loaded file type Firmware {version} (restart
required).
Example
WBM: User admin loaded file type Firmware V02.00.00 (restart required).
Explanation
The user has successfully loaded the firmware.
Severity
Notice
Facility
local0
Standard
IEC 62443-3-3 Reference: SR7.4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC632-2C and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC632-2C Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC632-2C
CategorySwitch
LanguageEnglish

Related product manuals