EasyManua.ls Logo

Siemens SIMATIC RF615R - Page 114

Siemens SIMATIC RF615R
490 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Readers
5.2 SIMATIC RF615R
SIMATIC RF600
114 System Manual, 11/2018, J31069-D0171-U001-A21-7618
6GT2811-6CC10-xAA0
Conditions relating to UL approval
for indoor use only (dry location)
Mounting height shall be equal or less than
2 m (MS1 classification according UL/IEC
62368-1).
La hauteur de montage doit être égale ou in-
férieure à 2 m (classification MS1 selon CEI
62368-1).
Degree of protection
IP67
Shock resistant to EN 60068-2-27
25.5 g
3)
Vibrations according to EN 60068-2-6
3.1 g
3)
Design, dimensions and weight
Dimensions (W × H × D)
140.5 × 133 × 45 mm
Weight
370 g
Type of mounting
Mounting rail Hanging
VESA 100 4x M4 screws;
1.5 Nm
Operation indicator
6 LEDs
Status display
1 LED (enclosure, all-round)
Standards, specifications, approvals
Proof of suitability EN 301 489-1 V2.2.0 / EN 301 489-3 V2.1.1 /
EN 302 208 V3.1.1
FCC CFR 47, Part 15 section 15.247
MTBF
29 years
1)
Measured at the output of the antenna socket.
2)
All supply and signal voltages must be safety extra low voltage (SELV/PELV according to
EN 60950). The voltage sources must meet the requirements of limited power sources (LPS) and
NEC Class 2.
Note that, depending on the power consumption, using extension cables > 20 m (6GT2891
-4FN50)
may lead to a voltage drop on the reader. This voltage drop can mean that the necessary mini-
mum voltage on the reader is below the required 20 V.
3)
The values for shock and vibration are maximum values and must not be applied continuously.
These values only apply to mounting using screws.