RF600 system planning
4.7 Chemical resistance of the readers and transponders
SIMATIC RF600
System Manual, 11/2018, J31069-D0171-U001-A21-7618
85
Substance
Test conditions
Evaluation
Concentration [%]
Temperature [°C]
1, 1, 1-Trichloroethane
Xylene
- 80 ℃ ++++
Zinc chloride (saturated)
-
80 ℃
++
-
75 ℃
++++
Explanation of the rating
++++
Resistant
+++ Practically resistant
++
Conditionally resistant
+
Less resistant
Not resistant
4.7.2.9 Polyvinyl chloride (PVC)
The following table provides an overview of the chemical resistance of the transponder made
of polyvinyl chloride (PVC).
Table 4- 14 Chemical resistance - polyvinyl chloride (PVC)
Substance
Test conditions
Evaluation
Concentration [%]
Temperature [°C]
Salt water
5 %
-
++++
Sugared water
10 %
-
++++
Acetic acid, w.
5 %
-
++++
Sodium carbonate, w.
5 %
-
++++
Ethyl alcohol, w.
60 %
-
++++
Ethylene glycol
50 %
-
++++
Fuel B
(acc. to ISO 1817)
- - ++++
Human sweat
-
-
++++
Explanation of the rating
++++
Resistant
++++
Practically resistant
++
Conditionally resistant
+
Less resistant
Not resistant
w.
Water solution