Accessories
10.1 Wide-range power supply unit for SIMATIC RF systems
SIMATIC RF600
470 System Manual, 11/2018, J31069-D0171-U001-A21-7618
10.1.7 Technical specifications
Table 10- 6 Technical specifications
Product type designation Wide-range power supply unit for SIMATIC RF
Insulation strength (prim./sec.) U
isol p/s
AC 3.3 kV
Primary- secondary side are galvanically isolated
ins
Leakage current I
leak
< 200 µA
in
Mains buffering t
h
≥ 50 ms
in
Power supply unit classification Level 3
Mechanical specifications
• Material
Polyamide, glass-fiber reinforced
Casting compound: Polyurethane
• Color
Black
Permitted ambient conditions
Ambient temperature
• During operation • -25 … +70 °C
• During transportation and storage • -40 … +85 °C
Self-heating on full-load
Surface temperature Max. +81.5 ℃
Degree of protection to EN 60529 IP67
Protection class according to SELV/PELV Separation of output voltage according to
Electrical safety EN 60950 / UL 60950 / CAN/CSA 22.2 950, 3
Conducted interference EN 61000-6-3 / EN 55011
Noise emission EN 61000-6-3 / EN 55011