5.2 SIMATIC RF615R
SIMATIC RF600
System Manual, 11/2018, J31069-D0171-U001-A21-7618
97
5.2 SIMATIC RF615R
5.2.1 Description
5.2.1.1 Overview
SIMATIC RF615R is a stationary reader in the UHF frequency band with an integrated
antenna. An external UHF RFID antenna can be connected via an RP-TNC connector.
The maximum transmit power is 400 mW at the reader output. A radiated power of up to
1000 mW ERP / 1400 mW EIRP is achieved when the appropriate antennas and antenna
cables are used. The interfaces (Ethernet, power supply, DI/DQ interface) are located on the
lower front edge. These interfaces can be used to connect the reader to the power supply
and a PC for parameter assignment.
The degree of protection is IP65.
Pos.
Description
RP-TNC interface
for connection of an external antenna
"PRESENCE" LED (PRE)
LED operating display
RS422 interface
1)
for connecting the power supply 24 V
DC: X80 DC24V
(M12, 8-pin)
DI/DQ interface: X10 DI/DQ
(M12, 12-pin)
Ethernet interface, TCP/IP: X1 P1
and Power over Ethernet
(M12, 4-pin)
1
) Connection of the readers to the ASM 456 communications module via the RS-422 interface.