RF600 system planning
4.7 Chemical resistance of the readers and transponders
SIMATIC RF600
System Manual, 11/2018, J31069-D0171-U001-A21-7618
73
4.7.2.2 Acrylonitrile/butadiene/styrene (ABS)
The following table provides an overview of the chemical resistance of the transponder made
of acrylonitrile/butadiene/styrene (ABS).
Table 4- 7 Resistance to chemicals - ABS
Substance
Test conditions
Evaluation
Concentration [%]
Temperature [°C]
Acetone - - ++
Alcohols
-
-
++
Gasoline
-
-
++++
Aliphatic hydrocarbons
-
-
++++
Aromatic hydrocarbons
-
-
ï¿®
Weak alkaline solutions
-
-
++++
Strong alkaline solutions
-
-
++++
Weak mineral acids
-
-
++++
Strong mineral acids
-
-
ï¿®
Perchloroethylene
-
-
++
Mineral lubricants
-
-
++++
Oxidizing acids
-
-
ï¿®
Weak organic acids
-
-
++++
Strong organic acids
-
-
++
Trichloroethylene
-
-
ï¿®
UV light and weathering
-
-
++
Hot water
(hydrolysis resistance)
- - ++++
Explanation of the rating
++++
Resistant
+++
Practically resistant
++
Conditionally resistant
+
Less resistant
ï¿® Not resistant

Table of Contents

Other manuals for Siemens SIMATIC RF615R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC RF615R and is the answer not in the manual?

Siemens SIMATIC RF615R Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC RF615R
CategoryRfid Systems
LanguageEnglish

Related product manuals