Transponder
7.9 SIMATIC RF622T
SIMATIC RF600
390 System Manual, 11/2018, J31069-D0171-U001-A21-7618
6GT2810-4HC80
Mechanical specifications
Material
PA12
Silicone-free
Yes
Color
Anthracite
Antenna material
Aluminum
Type of antenna
Shortened dipole
Printing
Can be printed using heat transfer technique
Permitted ambient conditions
Ambient temperature
In operation, during write/read access -25 ... +85 °C
In operation, outside write/read access -40 ... +85 °C
During transportation and storage -40 … +80 °C
Distance from metal ≥ 12 mm (with spacer)
Not suitable for mounting directly on metal
Degree of protection
IP67
Resistance to mechanical stress
Torsion and bending stress is not permitted
Shock resistant to EN 60068-2-27
100 g
3)
Vibration to EN 60068-2-6
50 g
3)
Design, dimensions and weight
Dimensions (L x W x D)
Transponder 120 × 30 × 6.5 mm
Spacer 130 × 31.5 × 12 mm
Weight
Transponder 14 g
Spacer 8 g
Type of mounting 2 x M4 screws
≤ 1 Nm
1)
In the current chip version of the transponder, the TID can be written to. It is not
recommended that you use the TID as user memory.
2)
The information relates to the maximum read range. You will find more information on
ranges in the section "Minimum distances and maximum ranges (Page 337)".
3)
The values for shock and vibration are maximum values and must not be applied
continuously.