Transponder
7.11 SIMATIC RF630T
SIMATIC RF600
404 System Manual, 11/2018, J31069-D0171-U001-A21-7618
6GT2810-2EC0x
Permitted ambient conditions
Ambient temperature
• In operation, during write/read access • -25 ... +85 °C
• In operation, outside write/read access • -40 ... +125 °C
• During transportation and storage • -40 … +125 °C
Distance from metal 0 mm
Designed for mounting directly on metal
Degree of protection
IP68 / IPx9K
Resistance to mechanical stress
Torsion and bending stress is not permitted
Shock-resistant according to DIN EN 60721-3-7,
Class 7 M3
100 g
3)
Vibration to EN 60068-2-6
20 g
3)
Design, dimensions and weight
Dimensions (∅ × D)
21 × 20 mm
Weight
22 g
Type of mounting Screw-in, SW 19 mm
≤ 6 Nm
Standards, specifications, approvals
MTBF
1712 years
1)
The range is reduced to 70% at the band limits 902 MHz or 928 MHz. Due to frequency
fluctuations, this effect has no impact.
2)
Mounting on a flat metal surface with a diameter of at least 150 mm and at room
temperature. The information relates to the maximum read range. You will find more
information on ranges in the section "Minimum distances and maximum ranges (Page 337)".
3)
The values for shock and vibration are maximum values and must not be applied
continuously.

Table of Contents

Other manuals for Siemens SIMATIC RF615R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC RF615R and is the answer not in the manual?

Siemens SIMATIC RF615R Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC RF615R
CategoryRfid Systems
LanguageEnglish

Related product manuals