When dealing with magnetic 󹪝elds, you must consider the requirements of DGUV rule 103-013
of the German Social Accident Insurance.
CAUTION
Handling secondary sections
The magnetic 󹪝elds of the secondary sections are permanent. When you come into direct
bodily contact with the secondary sections, a static magnetic 󹪞ux density of 2 T is not exceeded.
Observe DGUV rule 103-013, §14 "Systems with high static magnetic 󹪝elds".
WARNING
Risk of electric shock
Voltage is induced at the power connections of the primary section each time a primary section
moves with respect to a secondary section - and vice versa. If you touch the power connections
you may su󹪜er an electric shock.
Do not touch the power connections.
Connect the motor cable ports correctly, or insulate them properly.
Description
3.1Technical features and ambient conditions
Naturally-Cooled 1FN3 Linear Motors
Operating Instructions, 06/2023, A5E52220465B AB 31