4. Position the insertion aid so that a clearance of at least 1 cm remains between the cover band
and the secondary section track.
Figure5-10 Positioning the insertion aid
5. Slide the cover band under the slides until the secondary section end piece is reached.
Figure5-11 Sliding the cover band
6. Place the cover band in the wedge-shaped recess of the secondary section end piece and
align it in the traversing direction and at right angles to this, centered with respect to the end
piece.
Some clearance must be left between the end of the cover band and the threaded hole so
that the 󹪝xing screws of the clamping wedge can be inserted.
7. Place the clamping wedge down and press it into position.