Mounting the segmented cover
1. Mount the secondary sections with the slide plate removed.
2. Mount the 󹪝rst segment of the cover as follows:
Place the end of the 󹪝rst segment starting from the top in a 45° angle, 󹪞ush to the outer edge
of the last secondary section.
Then lower the segment in alignment with the secondary section track.
When you sense the magnetic attraction, let loose of the segment.
The segment generally assumes the correct position on its own.
Figure5-19 Mounting the 󹪝rst segment of the segmented cover
3. Check the correct position:
If the 󹪝rst segment of the cover extends to the middle of a secondary section, the position is
correct.
4. Mount all other segments the same way as the 󹪝rst segment.
Figure5-20 Mounting an additional segment of the segmented cover
Installation
5.3Procedure when installing the motor
Naturally-Cooled 1FN3 Linear Motors
82 Operating Instructions, 06/2023, A5E52220465B AB