1. The following data is copied from the Engineering System into the Volatile
data area of the C230-2 using the Download menu command:
Configuration data
Programs
Parameterizations
Technology packages
Baud rates, PROFIBUS DP addresses for the C230-2 (X8, X9) and the retain
variables are also stored in the Non-volatile data area.
2. Using the menu command Copy RAM to ROM, the following data is saved to
the Micro Memory Card from the Engineering System:
The technology packages and user data from the Volatile data area
Baud rate, PROFIBUS DP addresses, IP address, subnet dialog box and
router address and the Retain variables with their initial values from the
Non-volatile data area
Note:
The current values of the Retain variables are not saved to the Micro
Memory Card.
3. As the C230-2 ramps up, the SIMOTION Kernel (basic system) is loaded into
the system area of the Volatile data.
4. The contents of the Volatile data area are lost once the C230-2 is switched off.
When the C230-2 is switched on, the following data is transferred from the Mi-
cro Memory Card:
The technology packages and user data to the Volatile data area
Baud rate, PROFIBUS DP addresses, IP address, subnet dialog box and
router address and the Retain variables with their initial values to the
Non-volatile data area
5. The SIMOTION Kernel is written to the Non-volatile system through a Micro
Memory Card update.
If you want to install a newer or an older version of the SIMOTION Kernel that
is on the C230-2, you can use the Micro Memory Card to perform an update
(see Section 9.1).

Table of Contents

Other manuals for Siemens SIMOTION C230-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION C230-2 and is the answer not in the manual?

Siemens SIMOTION C230-2 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION C230-2
CategoryController
LanguageEnglish

Related product manuals