Climatic environmental conditions
The C230-2 may be used under the following climatic environmental conditions:
Environmental condi-
tions
Areas of application Remarks
Temperature:
For horizontal installation:
For vertical installation:
From 0 to 55° C
From 0 to 40° C
–
Relative humidity From 5 to 95 % Without condensation, complies
with Relative Humidity (RH) load-
ing factor 2 in accordance with
IEC 1131-2
Air pressure From 1080 to 795 hPa Corresponds to an altitude of
–1000 to 2000 m
Contaminant concentra-
tion
SO
2
: < 0.5 ppm;
Relative humidity < 60 %,
no moisture condensation
H
2
S: < 0.1 ppm;
Relative humidity < 60 %,
no moisture condensation
Test:
10 ppm; 4 days
1 ppm; 4 days
Mechanical environmental conditions
The mechanical environmental conditions for the C230-2 are shown in the follow-
ing table in the form of sinusoidal oscillations.
Frequency range (Hz) Continuous Occasional
10 v f v 58 0.0375 mm amplitude 0.075 mm amplitude