Component Function
Motors with
DRIVE-CLiQ interface
… allow simplified commissioning and diagnostics, as the motor and encoder type are iden‐
tified automatically.
DMC20/DME20
DRIVE-CLiQ hub
… enables the number of DRIVE-CLiQ interfaces to be increased and the creation of a point-
to-point topology.
Note
Please note that SIMOTION D410‑2 components in booksize format (Controller Extension,
Motor Modules, Line Modules, etc.) are not supported.
SIMOTION D410‑2 can only be used with the following Power Modules:
● PM340
● PM240-2 as of SIMOTION V4.4/SINAMICS V4.7
Other Power Modules are not supported by SINAMICS G120 (e.g. PM230).
Note
You will find detailed information on components in the SINAMICS S110/S120 family of
products in the SINAMICS S110/S120 manuals.
It is possible that older DRIVE‑CLiQ components can no longer be used with SIMOTION
D410‑2. You will find detailed information on this in the SIMOTION D410‑2 Commissioning
and Hardware Installation Manual in Section "Migration of SIMOTION D410 to
SIMOTION D410‑2" under "Permissible combinations".
See also
Permissible combinations
(Page 252)
Description
2.2 System components
SIMOTION D410-2