This permits a project download using remote maintenance or series commissioning.
Note
Note the SIMOTION version
The SIMOTION version on the target device must exactly match the version of the device on
which the backup was created.
After the upload of a SIMOTION project into the SIMOTION P320-4 (SIMOTION device
update), the time stamps in the user data and the SIMOTION SCOUT project are different.
The project is shown as inconsistent in SIMOTION SCOUT.
The consistency can be established via a project download or a download of the HW Config
in the SIMOTION SCOUT.
8VHUGDWD
:HEEURZVHU
(WKHUQHW
HJ
86%VWLFN
3*KDUGGLVN
HWF
([WHUQDOPHPRU\
6,027,213
)LUPZDUH
2SHUDWLQJV\VWHP
66'
&)DVWFDUG
6WRUDJHPHGLXP
LQWHUQDO
5HWDLQGDWD
.HUQHOGDWD
&XUUHQWGDWD
%DFNXSV
6WRUDJHPHGLXP
H[WHUQDO
&)DVWFDUG
6,027,213
6WRUDJHPHGLD
(QJLQHHULQJV\VWHP
6,027,213
65$0
5$0
Figure 10-5 SIMOTION SCOUT download (ZIP file)
Download of the project data process (ZIP file)
1. Save the data via SIMOTION SCOUT, menu Edit > Load to file system ... (option Save
compressed), on the file system of your programming device.
2. Transfer the ZIP file via the web browser and the project download of SIMOTION IT:
Manage Config > [Login dialog] > Device Update > Send new update data (*.ZIP)
3. The unpacking and the import of the data into the user data on the external CFast card is
performed automatically.
Commissioning (software)
10.8 Data storage concept
SIMOTION P320-4 E / P320-4 S
Commissioning and Hardware Installation Manual, 11/2016 163

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION Series and is the answer not in the manual?

Siemens SIMOTION Series Specifications

General IconGeneral
InterfacesPROFIBUS, PROFINET, Ethernet, USB
Programming LanguagesLAD, FBD
SafetyIntegrated safety functions
Typical ApplicationsMachine automation, robotics, packaging, printing
Relative Humidity5% to 95% (non-condensing)
Protection ClassIP20
CertificationsCE, UL, cUL