Figure 10-12 Restoring factory settings
Further information
on the SIMOTION P State - menus (Page 123)
10.8.5.3 Overall reset using SIMOTION P State - operating mode switch setting MRES
A general reset deletes the non-volatile SIMOTION data and retain data.
5HWDLQGDWD
.HUQHOGDWD
&XUUHQWGDWD
8VHUGDWD
%DFNXSV
6,027,21b3
)LUPZDUH
2SHUDWLQJV\VWHP
6,027,21b3
6WRUDJHPHGLD
6WRUDJHPHGLXP
LQWHUQDO
66'
&)DVWFDUG
6WRUDJHPHGLXP
H[WHUQDO
&)DVWFDUG
65$0
5$0
6,027,213
Figure 10-13 General reset
If a backup of the retain data (PMEMORY.XML) exists, this data will be accepted after the
general reset. Thus, the user can perform a general reset to force the saved retain data to be
restored.
Commissioning (software)
10.8 Data storage concept
SIMOTION P320-4 E / P320-4 S
170 Commissioning and Hardware Installation Manual, 11/2016