4.3.8 Dimension drawings, drilling dimensions for PM230 and PM240-2 Power Modules
utilizing push-through technology
The following dimension drawings and drilling patterns are not to scale.
Frame sizes FSA ... FSC
Panel thickness of the control cabinet ≤ 3.5 mm
+HLJKW
:LGWK
'HSWK
(OHFWULFDOFDELQHWFXWRXWDQGPRXQWLQJKROHV
0RXQWLQJKROHIRUWKHPRXQWLQJIUDPH
6KLHOG
SODWH
7
7
&8
23
DD
DD
G
)6$)6%
F
F
H
E
G
H
E
)6&
F
F
DDD
DDD
PP
PP
Figure 4-7 Dimension drawing and drilling dimensions for frame sizes FSA ... FSC
Table 4-20 Dimensions depend on the operator panel (OP) that is inserted
Frame
size
Width
[mm]
Height [mm] Mounting depth in the cabinet with
Control Unit (CU) [mm]
without shield
plate
with shield plate without OP with OP
1)
FSA 126 238 322 177 188
FSB 154 345 430 177 188
FSC 200 411 500 177 188
1)
BOP-2, IOP-2 or blanking cover