3.5.3 Line reactor
The line reactor supports the overvoltage protection, smoothes the
harmonics in the line supply and bridges commutation dips. For the
Power Modules subsequently listed, a line reactor is suitable in order
to dampen the specified effects.
The figure on the right-hand side shows as example the line reactors
for the PM240-2 Power Modules, FSB.
The line requirements for deployment of a line reactor depends on the Power Module:
Technical data (Page 435)
Line reactors for PM330, 380 V … 480 V
Power Module Power Line reactor
GX 6SL3310-1PE33‑0AA0 160 kW 6SL3000-0CE33-3AA0
6SL3310-1PE33‑7AA0 200 kW 6SL3000-0CE35-1AA0
6SL3310-1PE34-6AA0 250 kW
HX 6SL3310-1PE35-8AA0 315 kW 6SL3000-0CE36-3AA0
6SL3310-1PE36-6AA0 355 kW 6SL3000-0CE37-7AA0
6SL3310-1PE37-4AA0 400 kW
JX 6SL3310-1PE38-4AA0 450 kW 6SL3000-0CE38-7AA0
6SL3310-1PE38-8AA0,
6SL3310‑1PE41‑0AA0
500 kW … 560 kW 6SL3000-0CE41-0AA0
Line reactors for PM330 Power Modules, 500 V … 690 V
Power Module Power Line reactor
HX 6SL3310‑1PG33‑7AA0,
6SL3310‑1PG34‑0AA0,
6SL3310‑1PG34‑5AA0
315 kW … 400 kW 6SL3000-0CH34-8AA0
6SL3310-1PG35-2AA0 450 kW 6SL3000-0CH36-0AA0
JX 6SL3310-1PG35-8AA0 500 kW 6SL3000-0CH36-0AA0
6SL3310-1PG36-5AA0,
6SL3310‑1PG37‑2AA0
560 kW … 630 kW 6SL3000-0CH38-4AA0
Line reactors for PM240-2 Power Modules
A line reactor is not required.
Description
3.5 Components for the Power Modules
Converter with the CU230P-2 Control Units
44 Operating Instructions, 09/2017, FW V4.7 SP9, A5E34257946B AE