Performing basic parameterization
6.3 Drive axes
Getting Started, 12/2018, 6SL3097-5AG30-0BP0
153
Setting the technological application and selection of the motor data identification
1. Select one of the following applications in the "Technology application" (p0500) drop-
down list:
[0] Standard drive (VECTOR)
[1] Pumps and fans
[2] Encoderless control down to f = 0 (passive loads)
[3] Dynamic response in the field-weakening range
[4] Approach with high breakaway torque
[5] High load inertia
2. In the drop-down list "Motor data identification and rotating measurement" (p1900), select
how the motor data identification is to be carried out for a stopped motor:
[0] Disabled
[1] Motor data ident. (standstill) and speed controller opt.
[2] Motor data identification (standstill)
Motors from the motor list
For motors with DRIVE-CLiQ interface or motors from the motor list (see Chapter "Inserting
and specifying motors from the motor list (Page 88)"), no additional entries are required
when automatically calculating the motor/controller parameters.
Third-party motors
Motor and controller parameters must first be calculated for third-party motors and motors
that are not in the motor list.