Commissioning
5.4 Creating a project offline in Startdrive
Getting Started, 12/2018, 6SL3097-5AG30-0BP0
95
Adding additional encoders
If you require additional encoders for your device configuration, then you can configure these
in the same way. These encoders are then normally used as machine encoders.
Specifying the encoder evaluation
Precondition
You have already specified an encoder. The non-specified encoder evaluation is displayed.
Various Sensor Modules are available for the encoder evaluation. Different types are offered
for selection depending on the encoder.
1. Click on the non-specified encoder evaluation.
The Sensor Modules that are available are listed in the Inspector window.
Figure 5-28 Encoder evaluation specified
2. Select your Sensor Module.
The Sensor Module has been specified.