Commissioning
5.4 Creating a project offline in Startdrive
90 Getting Started, 12/2018, 6SL3097-5AG30-0BP0
The additionally activated subareas are displayed in the Inspector window under "Motor
details".
Figure 5-23 Motor specified
8. Acquire the required motor data of the inserted motor.
Note
The pink input fields are mandatory input fields. If appropriate values a
re not entered in
these fields, then the device configuration cannot be completed.
Note
We recommend entering the values in the inspector window under "Motor details".
Individual parameters may be locked in the parameter view and cannot be edited.
Result
The motor is specified with the manually acquired motor data. The white area turns dark
gray.
If you have selected a motor with encoder, the encoder and the encoder evaluation are also
added automatically.
5.4.5.4
Making detailed settings
You can configure the following motor details for motors during commissioning:
Basic parameter assignment
Rating plate values
Motor brake